| Basic Parameters: | |
|---|---|
| Operating Field | 6 T |
| Magnetic Length | 2.4 m |
| Operating Current | 15 kA |
| Operating Temperature | 4.5 K |
| Beam Aperture (HxW) | 80 x 100 mm |
| Tungsten Beam Tube Thickness | 10 mm |
| Operating Temperature of Beam Tube | 77 K |
| Coil: | |
| One Layer Cos(Phi) Type Design | |
| Number of Turns in Coil | 70 |
| Inductance | 12.5 mH |
| Stored Energy | 1.4 MJ | Structure: |
| Cold Mass Diameter | 410 mm |
| Length of Cold Mass | 3 m |
| Weight of Cold Mass | 3 t |
| Quadrupole Parameters: | |
|---|---|
| Operating Field | 3.6 T |
| Magnetic Length | 1.0 m |
| Operating Current | 10 kA |
| Operating Temperature | 4.5 K |
| Beam Aperture | 120 mm |
| Tungsten Beam Tube Thickness | 10 mm |
| Operating Temperature of Beam Tube | 77 K |
| Quadrupole Coil: | |
| One Layer Cos(Phi) Type Design | |
| Coil Inner Diameter | 160 mm |
| Sextupole Coil: | |
| One Layer Cos(Phi) Type Design | |
| Coil Inner Diameter | 220 mm |
| Horizontal Sextupole Poletip Field | 0.52 T |
| Vertical Sextupole Poletip Field | 1.03 T |
| Magnetic Length | 1.0 m | Structure: |
| Design Concept | Collared coil assembly of the quadrupole is installed inside aperture of sextupole with common iron yoke. |
| Common Cold Mass Diameter | 410 mm |
| Length of Cold Mass | 1.5 m |
| Weight of Cold Mass | 1.5 t |
| Design Concept: | |
|---|---|
| Common cold mass vessel for the arc half cell which will contain dipole, quadrupole and sextupole magnets. | |
| Common vacuum vessel for the cryostat. | |
| Two suspension posts and anchor in the middle of quadrupole. | Structure Parameters: |
| Cold Mass Diameter | 410 mm |
| Total Length of Cold Mass | 4.6 m |
| Beam Tube Length | 4.9 m |
| Total Weight of the Common Cold Mass | 4.5 t |
| Outer Diameter of Cryostat | 800 mm |
| Suspension Post Dimension (HxW) | 900 x 800 mm |
| Total Weight of the Half Cell Assembly | 5.5 t | Cryo-loads: |
| Static heat leaks: | |
| to He level, at 4.5 K | 5 W/cryostat |
| to N2 level, at 77 K | 30 W/cryostat |
| Dynamic heat losses: (Included beam losses) | |
| to He level, at 4.5 K | 7 W/cryostat |
| to N2 level, at 77 K | 70 W/cryostat |