A. Moretti 07/21/00 LIST OF 5 MW LINAC STATION COMPONENTS AND THEIR STATUS: 1. 7835 TETRODE CAVITY AMPLIFIER; CURRENTLY USED AS LINAC "HOT" SPARE (NEED PERMISSION TO USE IN LAB G); NEED TO PURCHASE 7835 TETRODE FROM SPARE PARTS OR BURLE. 2. RF DRIVER 250 kW; WAREHOUSE; GOOD CONDITION. 3. MODULATOR 50 kV DECK; WAREHOUSE; CABINET NEEDS TO BE BUILT OR PURCHASED; NEEDS REFURBISHING; MAY NEED NEW SWITCH TUBE ENGINEERING. AND OTHER PARTS. 4. CAPACITOR BANK; NEEDS TO BE PURCHASED AND BUILT; ITS CABINET NEEDS TO BE BUILT OR PURCHASED. 5. CROW BAR ARC PROTECTION; WAREHOUSE; GOOD CONDITION. 6. H.V. TRANSFORMER, 45kV; WAREHOUSE; OLD DESIGN MAYBE BETTER TO PURCHASED MODERN REPLACEMENT. 7. H.V. RECTIFIER, 50 kV; WAREHOUSE; OLD DESIGN MAYBE BETTER TO PURCHASED MODERN REPLACEMENT. 8. FILAMENT TRANSFORMER, 7V, 7000A; OLD DESIGN MAYBE BETTER TO PURCHASED MODERN REPLACEMENT.